Insulation Calculator
Start with surface area and a purchasing allowance, then choose a product family. Labeled R, thickness, and coverage determine quantities; a coverage count alone cannot establish thermal performance.
Your numbers
Start with the example below, then adjust it to your home.
Individual units required
- Installed surface area
- 800 sq ft
- Area with purchase allowance
- 840 sq ft
- Compatible nominal-R layers
- 1 layers
- Individual units per layer
- 84 units
- Whole purchase packs / bags
- 84 packs / bags
- Units in purchased packs
- 84 units
- Purchased coverage across all layers
- 840 sq ft
- Sum of layer nominal R
- 19 R
- Total labeled layer thickness
- 6 in
- Generic theoretical thickness only
- 5.94 in
An estimate, not a quote. Example rates are adjustable. See the assumptions below.
Estimate basis
Individual units are batts; the pack size is separate. Weight is unavailable without product-specific mass data.
Price unavailable: no cost is inferred or silently set to zero.
How this calculator works
Adjusted area = installed sq ft × (1 + purchasing allowance / 100). Compatible layers = ceil(target R / product nominal R). Units per layer = ceil(adjusted area / actual unit coverage); total units = units per layer × layers; packs = ceil(total units / units per pack). Blown bags = ceil(strictest chart requirement for adjusted area, plus applicable Minnesota supplemental bags). Bag weight = whole bags × labeled net mass. Pack budget = packs × price; optional all-in area budget = adjusted area × entered rate.
40 × 20 ft plus 5% gives 840 sq ft. One layer of 15-in × 8-ft batts needs 84 batts; 23-in × 8-ft batts need 55. Appropriate 32-sq-ft boards need 27 sheets per layer. R-19 / generic 3.2 gives 5.9375 theoretical inches, not a product specification. The optional reference budget is 840 × $0.65 = $546. At 1,000 sq ft plus 5%, two compatible R-19 layers of 10-sq-ft batts need 210 batts; the published AttiCat R-38 chart needs 20 bags, or 550 lb purchased.
Assumptions & what’s included
- Batt width is actual product width, not framing spacing. Rolls require entered coverage per individual roll. The example R-19 / 6-inch batt must be replaced with your label. A single-layer selection rejects an insufficient nominal R. Count pieces separately for each layer before rounding packs; no pooled offcut reuse is assumed.
- Generic theoretical thickness uses R-3.2/in for fiberglass and R-3.3/in for mineral wool only. It does not override product labels. Rigid XPS/EPS/polyiso require labeled R and thickness instead of a generic R-per-inch substitution. Weight is shown only for bags with a specified net mass.
- Nominal product R-values and thicknesses describe the selected product, not whole-assembly performance. Ideal layering requires compatible, properly installed, uncompressed products and adequate space. This tool does not certify cavity fit, code compliance, structural loading, or moisture design.
- The AttiCat US open-attic chart was retrieved 2026-11-16 from Owens Corning (27.5-lb bag). Its webpage has no explicit revision identifier; verify the current bag label. Only published R rows are supported. The strictest minimum-bag, maximum-coverage, or minimum-weight requirement controls. Minnesota adds the published supplemental depth and bags. This application choice is independent of wage location.
- Cellulose and other loose fill require an actual bag-label row: R, minimum bags per 1,000 sq ft, bag mass, initial depth, and settled depth, plus any maximum-coverage/minimum-weight columns. Greenfiber's current chart was inaccessible during verification, so no unverified Greenfiber production preset is supplied. Initial and settled depths are separate; no second settlement factor is added.
- Additional purchasing allowance increases bought material only; it cannot establish the required installed thickness. No interpolation or extrapolation of coverage tables is performed. Board sheet coverage is not a cutting-layout solution.
- Dimensions are normalized to feet and square feet; changing display units preserves the physical measurement. Inputs have explicit finite limits. Missing active inputs are errors, while an explicitly entered zero price is valid.
- Full precision is retained until display. Money displays to cents using half-up rounding for these nonnegative costs; individually rounded lines may differ by a cent from their sum. Discrete purchases round upward before display, without subtracting an epsilon. Siding squares remain an area measure.
- Defaults and reference price, weight, productivity, burden, markup, and fee allowances are adjustable examples observed November 16, 2026, not verified current supplier prices or universal recommendations. Confirm product labels, scope, and written quotes before ordering.
A few common questions
Why does increasing R change the quantity?
With a fixed labeled product, an explicitly compatible layered estimate needs more layers. A single-layer estimate instead rejects a target above the selected product R. Neither result certifies the assembly.
Why can bag counts exceed the minimum-bags column?
Manufacturer columns are rounded. The calculation also honors maximum coverage and minimum mass so that choosing a more convenient column cannot understate the published requirements.